Národní úložiště šedé literatury Nalezeno 10 záznamů.  Hledání trvalo 0.01 vteřin. 
Saving power and area with multi-bit pulsed latches
Král, Vojtěch ; Horský, Pavel (oponent) ; Dřínovský, Jiří (vedoucí práce)
This thesis describes types of power consumption in CMOS technology and low power techniques that can be used in application-specific integrated circuits. It describes a multi-bit pulsed latch as one of the low power techniques that can be used as a better replacement for a standard multi-bit master-slave flip flop. The multi-bit pulsed latch is composed of two parts: a pulse generator and a pulsed latch. Different useful topologies are mentioned. Topologies are chosen for their optimized area and power consumption. A schematic of the multi-bit pulsed latch is designed from chosen topologies and compared to a schematic of the standard multi-bit flip flop. Required layouts of multi-bit pulsed latches are then made and compared to standard layouts of multi-bit flip flops. Those designed multi-bit pulsed latches are also simulated in a simple design.
Přístroj pro elektroterapii
Kopečný, Josef ; Kolář, Radim (oponent) ; Chmelař, Milan (vedoucí práce)
V úvodu této práce jsou popsány základy fyziatrické léčby. Podrobněji se zde rozebírá elektroléčba a to jak z hlediska vedení proudu tkáněmi tak i z hlediska využití nejrůznějších druhů proudů, které se pro tuto léčbu používají. Také jsou zde zmíněny elektrody a přechod proudu mezi elektrodou a pokožkou. Závěrečná část je věnována návrhu a realizaci jednoduchého přístroje pro tuto terapii.
Zdroj pro pulzní magnetronové naprašování
Schulz, Jakub ; Magát, Martin (oponent) ; Šteffan, Pavel (vedoucí práce)
Předkládaná práce se zabývá návrhem a konstrukcí generátoru pro magnetronové naprašování. Navržené zařízení je schopné generovat dva výstupní signály s obdélníkovým průběhem v protitaktním režimu. U obou výstupů lze nezávisle nastavit frekvenci, počet impulzů a střídu. Zdrojem obou signálů jsou dvě frekvenční syntézy řízené mikrokontrolerem PIC16F877A. Všechny parametry se nastavují pomocí čtyř tlačítek a jsou zobrazovány na alfanumerickém displeji s 16x4 znaky. Úprava střídy je realizována pomocí speciálního modulu.
Saving area and power consumption in 65 nm digital standard cell library
Král, Vojtěch
This study aims to investigate multi-bit pulsed latches in comparison with multi-bit flip flops as one of the low-power solutions in 65 nm technology process. Topologies of pulse generators and multi-bit pulsed latches were investigated to find out which can be more suitable. The pulse generator was chosen because of its low power and a small area in comparison with other options. The pulse generator is made of a simple AND logical gate and a double-stacked inverter. The pulsed latch was also chosen because of its low power, small area, and reliability of the circuit. The chosen topology is modified PPCLA. Simulations of the chosen topology had shown that multi-bit flip flops could be replaced with more effective multi-bit pulsed latches.
SMV-2022-61: Vývoj pokročilého programovatelného akvizičního systému s generátorem pulzů
Vondra, Vlastimil
Posouzení specifikace zařízení z hlediska možností realizace zařízení pomocí přístrojového vybavení zhotovitele. Analýza požadavků zadání a vývoj metodiky řešení generátoru. Vypracování návrhu realizace dle požadovaných vlastností. Výroba mechanických a elektrických částí a nákupu potřebných komponent. Ověření teoretických výchozích požadavků zadání praktickým měřením v určeném místě. Zkompletování 1 kusu experimentálního zařízení. Instalace, kalibrace zařízení na místě plnění.\n
Saving power and area with multi-bit pulsed latches
Král, Vojtěch ; Horský, Pavel (oponent) ; Dřínovský, Jiří (vedoucí práce)
This thesis describes types of power consumption in CMOS technology and low power techniques that can be used in application-specific integrated circuits. It describes a multi-bit pulsed latch as one of the low power techniques that can be used as a better replacement for a standard multi-bit master-slave flip flop. The multi-bit pulsed latch is composed of two parts: a pulse generator and a pulsed latch. Different useful topologies are mentioned. Topologies are chosen for their optimized area and power consumption. A schematic of the multi-bit pulsed latch is designed from chosen topologies and compared to a schematic of the standard multi-bit flip flop. Required layouts of multi-bit pulsed latches are then made and compared to standard layouts of multi-bit flip flops. Those designed multi-bit pulsed latches are also simulated in a simple design.
Design Of The Pulse Generator For Testing And Validating Partial Discharge Measuring Systems
Hejtmánek, Tomáš
This article deals with the design and implementation of a pulse generator serving as acalibration generator for setting up measuring systems for monitoring the activity of partial discharges(PD) in the high-voltage power transformers or gas insulated switchgears (GIS). After installingthe measuring device, it is advisable to test the entire measuring chain and, if necessary, setparameters that would affect the correct detection of PD signals. Calibration pulse generators areused for setting and validating measuring chain. These are usually used in systems that sense theelectromagnetic activity of PD. Correct and timely detection of PD can avert a transformer accidentand thus contribute to higher safety in power plants. The proposed generator should serve as theoutput part of a programmable generator, which did not reach sufficient parameters of output pulses.The goal was to achieve a rising time around 100 ps and an amplitude of more than 6 V usingmodern and very fast operational amplifiers and step recovery diodes as a sharpener of the inputpulse. The measurements show waveform of the output voltage pulse.
Pulse Generator for Φ-OTDR in VPI photonics
Čučka, Milan
The paper focuses on Φ–OTDR (Optical Time Domain Reflectometry) systems which need short time duration and high powered pulses for proper function, because the backscattered signal is weak for proper detection. The article includes a simulation of the signal generator for Φ–OTDR sensoric systems in simulation software. Designed generator allows to try pulses, with different time of duration, pulse repetition frequency and power. The article also includes scientific notation of backscattered signal and a short description of the used systems.
Přístroj pro elektroterapii
Kopečný, Josef ; Kolář, Radim (oponent) ; Chmelař, Milan (vedoucí práce)
V úvodu této práce jsou popsány základy fyziatrické léčby. Podrobněji se zde rozebírá elektroléčba a to jak z hlediska vedení proudu tkáněmi tak i z hlediska využití nejrůznějších druhů proudů, které se pro tuto léčbu používají. Také jsou zde zmíněny elektrody a přechod proudu mezi elektrodou a pokožkou. Závěrečná část je věnována návrhu a realizaci jednoduchého přístroje pro tuto terapii.
Zdroj pro pulzní magnetronové naprašování
Schulz, Jakub ; Magát, Martin (oponent) ; Šteffan, Pavel (vedoucí práce)
Předkládaná práce se zabývá návrhem a konstrukcí generátoru pro magnetronové naprašování. Navržené zařízení je schopné generovat dva výstupní signály s obdélníkovým průběhem v protitaktním režimu. U obou výstupů lze nezávisle nastavit frekvenci, počet impulzů a střídu. Zdrojem obou signálů jsou dvě frekvenční syntézy řízené mikrokontrolerem PIC16F877A. Všechny parametry se nastavují pomocí čtyř tlačítek a jsou zobrazovány na alfanumerickém displeji s 16x4 znaky. Úprava střídy je realizována pomocí speciálního modulu.

Chcete být upozorněni, pokud se objeví nové záznamy odpovídající tomuto dotazu?
Přihlásit se k odběru RSS.